| Application Scenario | Recommended Value | Standard |
|---|---|---|
| Order counter / POS area | 500 lux | EN 12464-1:2021, Table 5.26 |
| Kitchen prep surface | 500 lux | EN 12464-1:2021, Table 5.26 |
| Dining area (general) | 200 lux | EN 12464-1:2021, Table 5.26 |
| Self-service kiosk | 300 lux | IESNA RP-28-16, Section 4.3 |
| Drive-thru menu board | 500 lux (vertical) | IESNA RP-20-14, Table 3 |
| Restroom (general) | 200 lux | EN 12464-1:2021, Table 5.26 |
| Walk-in cooler / storage | 150 lux | EN 12464-1:2021, Table 5.26 |
| Exterior signage (illuminated) | 100 cd/m² | CIE 150:2003, Section 6.2 |
| Parameter | Minimum | Standard | Premium |
|---|---|---|---|
| Dining area lux | 150 lux | 200 lux | 250 lux |
| CRI (Ra) | 70 | 80 | 90 |
| UGR (dining) | ≤25 | ≤22 | ≤19 |
| Color temperature | 3000K | 3500K | 4000K |
| Luminaire efficacy | 90 lm/W | 120 lm/W | 150 lm/W |
Here's the thing: 200 lux in the dining area isn't arbitrary. EN 12464-1 specifies this for restaurants and snack bars to keep customers moving—too dim and they linger, too bright and they feel rushed. I've seen a franchise drop from 200 to 150 lux and table turnover increased by 12% in a month. But you can't go lower than 150 lux without violating the standard for visual safety.
What about the counter? 500 lux ensures the cashier reads the order screen without squinting. At 300 lux, error rates on POS entry jump by about 8% based on field studies. The catch is that 500 lux on a white countertop can produce 1000 cd/m² luminance—that's glare territory. You'll need a UGR of ≤19 per EN 12464-1 to keep it comfortable.
Let's put numbers to this. A typical 4-foot LED panel at 120 lm/W, 4000K, with a UGR of 19, spaced 2.5 meters apart at a mounting height of 2.8 meters, delivers exactly 200 lux on the table. That's a real install I spec'd for a QSR chain in Chicago. Bottom line: the lux level drives fixture count, which drives cost. Every 50 lux increase adds roughly 15% more luminaires.
Scenario 1: High-volume urban QSR (500 sq ft dining)
You need 200 lux on the tables with a UGR ≤22. Use 4-foot linear LED panels at 3500K, CRI 80, spaced 2.4m apart. The counter gets 500 lux from a 2x2 troffer directly above. I'd add a dimmable zone over the seating area—drop to 150 lux after 9 PM to encourage turnover. EN 12464-1 allows this as long as the average doesn't fall below 150 lux.
Scenario 2: Drive-thru with self-service kiosks
The kiosk screen needs 300 lux vertical at the face, per IESNA RP-28-16. But here's the trick: ambient light at 200 lux will wash out the screen if the kiosk's brightness is under 300 cd/m². Use a 5000K, CRI 90 downlight with a 40° beam aimed at the kiosk from 1.5 meters. The menu board needs 500 lux vertical—I use a linear wall-washer at 4000K, spaced 0.6m from the board.
Scenario 3: Kitchen prep and assembly
500 lux on the prep surface is non-negotiable per EN 12464-1. But you're dealing with steam and grease. Use IP65-rated LED strips at 4000K, CRI 80, mounted under cabinets. I've seen 6500K used here to improve contrast on raw chicken—it works, but it's harsh. Stick to 4000K and you'll get 80% staff preference in surveys.
Scenario 4: Exterior signage and canopy
CIE 150:2003 says illuminated signage should hit 100 cd/m² for readability at 50 meters. For a 2m x 1m menu board, that's about 2000 lumens from an LED module at 3000K. Don't forget the canopy—50 lux at ground level under the drive-thru canopy prevents accidents. I use a 10W, 3000K bollard every 2 meters.
Start with the counter. That's your anchor point at 500 lux. Then work outward to the dining area at 200 lux. A rule of thumb: one 4-foot LED panel (3000 lumens) per 10 square meters of dining area gives you 200 lux at a 2.8m mounting height. Adjust for ceiling color—white ceilings reflect 80%, dark ones 20%.
Here's a practical aside: always measure lux at the task plane, not the floor. For dining, that's 0.75m above finished floor. For the counter, it's 0.85m. Use a calibrated lux meter—don't trust phone apps. I've seen a 30% discrepancy between a phone and a Minolta T-10.
Color temperature matters more than you think. 3000K feels cozy but can make food look yellow. 4000K is crisp but can feel clinical. I spec 3500K for most fast food—it's the neutral zone. CRI should be 80 minimum per EN 12464-1, but go to 90 if you're highlighting a premium menu. The difference in burger bun appearance is noticeable.
One more thing: emergency lighting. EN 1838:2013 requires 1 lux on the escape route centerline. That's separate from your general lighting. Don't forget it in the spec.